Is Your Reverse Osmosis TDS Actually Normal?
A raw TDS meter reading alone cannot tell you if an RO membrane is healthy. A 25 ppm reading means 95% rejection on 500 ppm hard tap water, but only 58% rejection on 60 ppm soft water.
Use this calculator to compute your true rejection percentage, separate real membrane wear from TDS creep or remineralization cartridges, and follow verified next steps based on NSF/ANSI 58 and WQA maintenance benchmarks.
RO TDS Rejection Calculator
Where You Sample Changes the Reading
Most false membrane replacements happen because homeowners measure TDS at the kitchen RO faucet without realizing a 6th-stage alkaline cartridge sits downstream of the membrane, or because the first glass of water absorbed standing ions overnight.
Worked Examples You Can Verify
Example 1: Standard 5-Stage RO (Healthy)
Cold tap reads 320 ppm; flushed RO faucet reads 19 ppm.
Rejection = (1 − 19 / 320) × 100 = 94.1%
Example 2: 6-Stage Alkaline RO (False Alarm)
Cold tap reads 250 ppm; faucet reads 55 ppm (78% apparent).
Because a remineralization stage adds ~35–40 ppm of beneficial minerals, testing before the mineral stage typically reveals 12–18 ppm (>92% rejection).
Next Diagnostic Steps
| Observed Symptom | Most Likely Cause | Recommended Tool / Guide |
|---|---|---|
| Drain water runs continuously hours after closing faucet | Low tank air charge (<7 psi), faulty ASO valve, or feed pressure <40 psi | Continuous Drain & Pressure Triage |
| First cup TDS is high, then drops after 30–60 seconds | Normal overnight osmotic diffusion (TDS creep) | TDS Creep & Sampling Guide |
| Slow trickle from faucet, TDS still low (<10% of tap) | Clogged sediment/carbon pre-filters or waterlogged tank bladder | Membrane vs. Pre-Filter Matrix |
| Planning annual filter and membrane budget | 6–12 mo pre-filters + 2–4 yr membrane schedule | Filter Cost & Schedule Planner |